[SX126x] Fixed packet length in LoRa implicit mode
This commit is contained in:
parent
0210e10a24
commit
ece2621a6f
1 changed files with 6 additions and 0 deletions
|
@ -1287,6 +1287,12 @@ float SX126x::getFrequencyError() {
|
||||||
|
|
||||||
size_t SX126x::getPacketLength(bool update) {
|
size_t SX126x::getPacketLength(bool update) {
|
||||||
(void)update;
|
(void)update;
|
||||||
|
|
||||||
|
// in implicit mode, return the cached value
|
||||||
|
if((getPacketType() == RADIOLIB_SX126X_PACKET_TYPE_LORA) && (_headerType == RADIOLIB_SX126X_LORA_HEADER_IMPLICIT)) {
|
||||||
|
return(_implicitLen);
|
||||||
|
}
|
||||||
|
|
||||||
uint8_t rxBufStatus[2] = {0, 0};
|
uint8_t rxBufStatus[2] = {0, 0};
|
||||||
_mod->SPIreadStream(RADIOLIB_SX126X_CMD_GET_RX_BUFFER_STATUS, rxBufStatus, 2);
|
_mod->SPIreadStream(RADIOLIB_SX126X_CMD_GET_RX_BUFFER_STATUS, rxBufStatus, 2);
|
||||||
return((size_t)rxBufStatus[0]);
|