diff --git a/src/modules/LLCC68/LLCC68.h b/src/modules/LLCC68/LLCC68.h index 3a737060..c7b09c6f 100644 --- a/src/modules/LLCC68/LLCC68.h +++ b/src/modules/LLCC68/LLCC68.h @@ -36,9 +36,10 @@ class LLCC68: public SX1262 { If you are seeing -706/-707 error codes, it likely means you are using a module with TCXO. To use TCXO, either set this value to its reference voltage, or set SX126x::XTAL to false. \param useRegulatorLDO Whether to use only LDO regulator (true) or DC-DC regulator (false). Defaults to false. + \param rampTime The time delayed to allow the PA to ramp up. Defaults to 200 us. \returns \ref status_codes */ - int16_t begin(float freq = 434.0, float bw = 125.0, uint8_t sf = 9, uint8_t cr = 7, uint8_t syncWord = RADIOLIB_SX126X_SYNC_WORD_PRIVATE, int8_t pwr = 10, uint16_t preambleLength = 8, float tcxoVoltage = 0, bool useRegulatorLDO = false); + int16_t begin(float freq = 434.0, float bw = 125.0, uint8_t sf = 9, uint8_t cr = 7, uint8_t syncWord = RADIOLIB_SX126X_SYNC_WORD_PRIVATE, int8_t pwr = 10, uint16_t preambleLength = 8, float tcxoVoltage = 0, bool useRegulatorLDO = false, uint8_t rampTime = RADIOLIB_SX126X_PA_RAMP_200U); // configuration methods