[SX126x] Added comments about TCXO/XTAL (#784)
This commit is contained in:
parent
a9a125a385
commit
ac15b9ae7d
2 changed files with 12 additions and 4 deletions
|
@ -38,7 +38,9 @@ class SX1262: public SX126x {
|
|||
\param syncWord 1-byte LoRa sync word. Defaults to RADIOLIB_SX126X_SYNC_WORD_PRIVATE (0x12).
|
||||
\param power Output power in dBm. Defaults to 10 dBm.
|
||||
\param preambleLength LoRa preamble length in symbols. Defaults to 8 symbols.
|
||||
\param tcxoVoltage TCXO reference voltage to be set on DIO3. Defaults to 1.6 V, set to 0 to skip.
|
||||
\param tcxoVoltage TCXO reference voltage to be set on DIO3. Defaults to 1.6 V.
|
||||
If you are seeing -706/-707 error codes, it likely means you are using non-0 value for module with XTAL.
|
||||
To use XTAL, either set this value to 0, or set SX126x::XTAL to true.
|
||||
\param useRegulatorLDO Whether to use only LDO regulator (true) or DC-DC regulator (false). Defaults to false.
|
||||
\returns \ref status_codes
|
||||
*/
|
||||
|
@ -52,7 +54,9 @@ class SX1262: public SX126x {
|
|||
\param rxBw Receiver bandwidth in kHz. Defaults to 156.2 kHz.
|
||||
\param power Output power in dBm. Defaults to 10 dBm.
|
||||
\param preambleLength FSK preamble length in bits. Defaults to 16 bits.
|
||||
\param tcxoVoltage TCXO reference voltage to be set on DIO3. Defaults to 1.6 V, set to 0 to skip.
|
||||
\param tcxoVoltage TCXO reference voltage to be set on DIO3. Defaults to 1.6 V.
|
||||
If you are seeing -706/-707 error codes, it likely means you are using non-0 value for module with XTAL.
|
||||
To use XTAL, either set this value to 0, or set SX126x::XTAL to true.
|
||||
\param useRegulatorLDO Whether to use only LDO regulator (true) or DC-DC regulator (false). Defaults to false.
|
||||
\returns \ref status_codes
|
||||
*/
|
||||
|
|
|
@ -37,7 +37,9 @@ class SX1268: public SX126x {
|
|||
\param syncWord 1-byte LoRa sync word. Defaults to RADIOLIB_SX126X_SYNC_WORD_PRIVATE (0x12).
|
||||
\param power Output power in dBm. Defaults to 10 dBm.
|
||||
\param preambleLength LoRa preamble length in symbols. Defaults to 8 symbols.
|
||||
\param tcxoVoltage TCXO reference voltage to be set on DIO3. Defaults to 1.6 V, set to 0 to skip.
|
||||
\param tcxoVoltage TCXO reference voltage to be set on DIO3. Defaults to 1.6 V.
|
||||
If you are seeing -706/-707 error codes, it likely means you are using non-0 value for module with XTAL.
|
||||
To use XTAL, either set this value to 0, or set SX126x::XTAL to true.
|
||||
\param useRegulatorLDO Whether to use only LDO regulator (true) or DC-DC regulator (false). Defaults to false.
|
||||
\returns \ref status_codes
|
||||
*/
|
||||
|
@ -51,7 +53,9 @@ class SX1268: public SX126x {
|
|||
\param rxBw Receiver bandwidth in kHz. Defaults to 156.2 kHz.
|
||||
\param power Output power in dBm. Defaults to 10 dBm.
|
||||
\param preambleLength FSK preamble length in bits. Defaults to 16 bits.
|
||||
\param tcxoVoltage TCXO reference voltage to be set on DIO3. Defaults to 1.6 V, set to 0 to skip.
|
||||
\param tcxoVoltage TCXO reference voltage to be set on DIO3. Defaults to 1.6 V.
|
||||
If you are seeing -706/-707 error codes, it likely means you are using non-0 value for module with XTAL.
|
||||
To use XTAL, either set this value to 0, or set SX126x::XTAL to true.
|
||||
\param useRegulatorLDO Whether to use only LDO regulator (true) or DC-DC regulator (false). Defaults to false.
|
||||
\returns \ref status_codes
|
||||
*/
|
||||
|
|
Loading…